PRODUCT CENTER


PRODUCT CENTER

Composite gas detector

The car specification level chip and imported intelligent sensor technology, as well as the self-developed precision compensation algorithm, are used. They have the characteristics of longevity noodles, high precision, high repeatability, high stability, and good temperature and humidity characteristics. The product integrates temperature and multiple gas (optional) concentration parameter detection. The design meets the harsh requirements of harsh industrial environments and is manufactured in strict accordance with national standards. The product is easy to operate and maintain, and is widely used in general industrial fields such as lithium battery energy storage, petrochemical industry, metallurgical coking, urban pipe gallery, wastewater treatment, energy generation, chemical storage and transportation, etc.

Keyword:

SENSOR Vehicle specification level high-precision

DESCRIPTION

The car specification level chip and imported intelligent sensor technology, as well as the self-developed precision compensation algorithm, are used. They have the characteristics of longevity noodles, high precision, high repeatability, high stability, and good temperature and humidity characteristics. The product integrates temperature and multiple gas (optional) concentration parameter detection. The design meets the harsh requirements of harsh industrial environments and is manufactured in strict accordance with national standards. The product is easy to operate and maintain, and is widely used in general industrial fields such as lithium battery energy storage, petrochemical industry, metallurgical coking, urban pipe gallery, wastewater treatment, energy generation, chemical storage and transportation, etc.
Product appearance

1

Application Scenario
Working temperature range: -25 ℃~+60 ℃;
Storage temperature range: -40 ℃~+70 ℃;
Humidity range: 10%~95% RH (without frost);
Pressure range: 86kPa~115kPa.
technical parameter

 

Parameter Parameter value
Detect gas Combustible gases, toxic and harmful gases
Detection Principle Electrochemical, catalytic combustion, semiconductor, PID options
measuring range Please refer to the list of measurable gases on P47-48 for details
measurement accuracy

±3%F·S

response time

T90<25s(The response time varies depending on the detected gas)

Explosion proof level

Ex  ib  IIC  T6  Gb

protection grade

IP66

authentication certificate

3C/CE/CPA

Power consumption

≤3W

working voltage

7-26V DC(Typical value24V DC)

Interface

RS485/3.51mm-5P

Communication protocol

RS485ModbusCommunication protocol (customizable)

Output Relay output (customizable)
Display method

12232LCDDot matrix LCD display

Shell Material Sprayed carbon steel
electrical interface Customizable according to needs
Dimensions

122×32×47mm

Weight Approximately 0.2kg (excluding connector tail accessories and cables)

 

Sensor specifications

 

sensor type Detect gas
catalytic combustion Combustible gases such as alkanes and gasoline

semiconductor

Combustible gases such as alcohols and esters
infrared Combustible gases such as alkanes, olefins, toluene, etc
electrochemistry Toxic and harmful gases such as oxygen and hydrogen sulfide

Photoion(PID)

Volatile organic compounds(VOC)

 

Sensor characteristics

 

sensor type Detect gas
catalytic combustion Linear output, good stability, high sensitivity, suitable for most combustible gas detection, with good anti poisoning and low attenuation rate
semiconductor Imported brand with high sensitivity and fast response, capable of detecting the majority of VOC vapors, long service life, and high cost-effectiveness
infrared Infrared dual compensation technology, high sensitivity, stable performance, no poisoning, low power consumption, can work in anaerobic environments, fast response, and long service life
electrochemistry Imported brand, high precision, linear output, strong selectivity, used for toxic and harmful gas detection

Photoion(PID)

Imported brand, with extremely high progress, linear output, fast response, suitable for detecting most volatile organic compounds (VOCs)

 

Gas Type

 

sensor type Gas Type Standing detection range operation temperature Life (months)
catalytic combustion Gas

0~100%LEL

-40~70℃

72

semiconductor Gas

0~100%LEL

-40~70℃

120

Infrared absorption type Gas

0~100%LEL

-40~70℃

120

Infrared absorption type carbon dioxide

0~500ppm/1000ppm/5000ppm0~2%VOL/5%VOL/100%VOL

-40~70℃

120

Photoion(PID)

Volatile organic compounds(VOC)

0~2000ppm(Specific ranges of different VOL substances are determined based on the situation)

-40~70℃

24

 

Gas detection type

 

Serial Number Type of gas being measured Range (optional, customizable) principle

1

carbon monoxide CO

0-1000ppm

electrochemistry

2

CO (with H2 compensation)

0-200/1000ppm

electrochemistry

3

hydrogen sulfideH2S

0-50/100/200/1000/5000ppm

electrochemistry

4

oxygenO2

0-25%vol

electrochemistry

5

nitrogen dioxideNO2

0-1/20/500ppm

electrochemistry

6

nitric oxideNO

0-1/100/1000ppm

electrochemistry

7

sulfur dioxideSO2

0-1/20/100/2000ppm

electrochemistry

8

chlorineCL2

0-20/200/2000ppm

electrochemistry

9

ammoniaNH3

0-50/100/1000/5000ppm

electrochemistry

10

hydrogenH2

0-1000/10000/20000ppm

electrochemistry

11

H2 (with CO compensation)

0-20000ppm

catalytic combustion

12

phosphinePH3

0-5/20/1000ppm

electrochemistry

13

formaldehydeCH2O

0-5/10/50/1000ppm

electrochemistry

14

ozoneO3

0-1/5/20/100/1000ppm

electrochemistry

15

FluorineF2

0-1ppm

electrochemistry

16

hydrogen fluorideHCL

0-20/200/1000ppm

electrochemistry

17

Hydrogen chlorideHCL

0-20/200/1000ppm

electrochemistry

18

hydrogen bromideHBr

0-20/200/1000ppm

electrochemistry

19

ethylene oxideETO

0-20/100ppm

electrochemistry

20

methyl mercaptanCH3SH

0-20/100ppm

electrochemistry

21

TetrafluorothiopheneC4H8S

0-50mg/m3

electrochemistry

22

silaneSIH4

0-50ppm

electrochemistry

23

Fluorine dioxideCLO2

0-20/200/1000ppm

electrochemistry

24

hydrogen cyanideHCN

0-50/100ppm

electrochemistry

25

ethyleneC2H4

0-10/200/1500ppm

electrochemistry

26

hydrogen peroxideH202

0-100/500/2000ppm

electrochemistry

27

GasEX

0-100%LEL

catalytic combustion

28

refrigerantFRON

0-1000/2000ppm

infrared

29

nitrous oxideN2O

0-1000/2000ppm

infrared

30

carbon dioxideCO2

0-2000/5000/1%/5%/20%/50%/100%VOL

infrared

31

sf6SF6

0-1000/2000ppm

infrared

32

methaneCH4

0-100%LEL

catalytic combustion

33

Organic volatilesVOC

0-1000ppm

semiconductor